What you need to know to order.
Analog Output
Features
Internally regulated
Bipolar input/output
The Analog clinometer is a signal conditioned sensor which has been
designed for dc voltage, bipolar operation. The clinometer requires a bipolar
supply of ±8 to ±15 VDC and delivers an output of ±3.6 VDC. This device is
internally regulated for various applications. The output scale is fixed at a
nominal 60mV per degree not dependent on the supply voltage. The Analog
clinometer has full EMI and ESD suppression circuitry on every line.
Model Number Description
0211 1002-000
0211 1102-000
Analog
Vertical Flange
Horizontal Flange
Analog Electrical Specifications
Voltage
Voltage Supply
Nominal
±12 VDC
Range (regulated)
±8 to ±15 VDC
Current 5 mA/supply
Scale Factor
60 mV/degree ±10%
Load Resistance (min.) 10 k0hms
Level Output (0°)
0 VDC
Wire Source
Black Power ground
Red +8 to +15 VDC
Gray -8 to -15 VDC
Blue Signal output
(reference to power ground)
Electrical Connections
AccuStar
Electronic Clinometer
Lucas Control Systems
1000 Lucas Way
Hampton, VA 23666
Phone: (757) 766-1500
Fax: (757) 766-4458
Internet: www.schaevitz